ISSN 1507-2711
JOURNAL DOI: dx.doi.org/10.17531/ein
Our IF is 1.145
JCR Journal Profile


Członek(Member of): Europejskiej Federacji Narodowych Towarzystw Eksploatacyjnych  - European Federation of National Maintenance Societies  Wydawca(Publisher):Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne (Warszawa) - Polish Maintenance Society (Warsaw)   Patronat Naukowy(Scientific supervision): Polska Akademia Nauk o/Lublin  - Polish Akademy of Sciences Branch in Lublin  Członek(Member of): Europejskiej Federacji Narodowych Towarzystw Eksploatacyjnych  - European Federation of National Maintenance Societies

 


Publisher:
Polish Maintenance Society
(Warsaw)

Scientific supervision:
Polish Academy of Sciences Branch in Lublin

Member of:
European Federation
of National Maintenance Societies


Attention!

In accordance with the requirements of citation databases, proper citation of publications appearing in our Quarterly should include the full name of the journal in Polish and English without Polish diacritical marks, i.e. "Eksploatacja i Niezawodnosc – Maintenance and Reliability".


 

Submission On-Line

 




 

Impact Factor

Impact Factor

Impact Factor

Impact Factor

SCImago Journal & Country Rank

MOST CITED

Update: 2017-08-25

1. ON APPROACHES FOR NON-DIRECT DETERMINATION OF SYSTEM DETERIORATION
By: Valis, David; Koucky, Miroslav; Zak, Libor

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Issue: 1   Pages: 33-41   Published: 2012

Times Cited: 36
2. UTILIZATION OF DIFFUSION PROCESSES AND FUZZY LOGIC FOR VULNERABILITY ASSESSMENT
By: Valis, David; Pietrucha-Urbanik, Katarzyna

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Volume: 16   Issue: 1   Pages: 48-55   Published: 2014

Times Cited: 28
3. SELECTED ASPECTS OF PHYSICAL STRUCTURES VULNERABILITY - STATE-OF-THE-ART
By: Valis, David; Vintr, Zdenek; Malach, Jindrich

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Issue: 3 Pages: 189-194 Published: 2012

Times Cited: 26
4. PREDICTING THE TOOL LIFE IN THE DRY MACHINING OF DUPLEX STAINLESS STEEL
By: Krolczyk, Grzegorz; Gajek, Maksymilian; Legutko, Stanislaw

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Volume: 15 Issue: 1 Pages: 62-65 Published: 2013

Times Cited: 23
5. RELIABILITY BASED OPTIMAL PREVENTIVE MAINTENANCE POLICY OF SERIES-PARALLEL SYSTEMS
By: Peng Wei; Huang Hong-Zhong; Zhang Xiaoling; et al.

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Issue: 2 Pages: 4-7 Published: 2009

Times Cited: 23
6. MAINTENANCE DECISION MAKING BASED ON DIFFERENT TYPES OF DATA FUSION
By: Galar, Diego; Gustafson, Anna; Tormos, Bernardo; et al.
EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY 
Issue: 2   Pages: 135-144   Published:2012

Times Cited: 20
7. COMPUTER-AIDED MAINTENANCE AND RELIABILITY MANAGEMENT SYSTEMS FOR CONVEYOR BELTS
By: Mazurkiewicz, Dariusz

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Volume: 16   Issue: 3   Pages: 377-382   Published: 2014

Times Cited: 18
8. A NEW FAULT TREE ANALYSIS METHOD: FUZZY DYNAMIC FAULT TREE ANALYSIS
By: Li, Yan-Feng; Huang, Hong-Zhong; Liu, Yu; et al.

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Issue: 3 Pages: 208-214 Published: 2012

Times Cited: 17
9. ANALYSIS OF TRANSPORTATION SYSTEM WITH THE USE OF PETRI NETS
By: Kowalski, Marcin; Magott, Jan; Nowakowski, Tomasz; et al.
EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY 
Volume: 15   Issue: 1   Pages: 48-62   Published: 2011

Times Cited: 15
10. PRODUCTIVITY AND RELIABILITY IMPROVEMENT IN TURNING INCONEL 718 ALLOY - CASE STUDY
By: Zebala, Wojciech; Slodki, Bogdan; Struzikiewicz, Grzegorz

EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Volume: 15   Issue: 4   Pages: 421-426   Published: 2013

Times Cited: 14
 

 

Visits since 2016.06.29:
darmowe liczniki


Andrzej KOMOREK

Investigation of ballistic resistance of adhesive bonded multi-layer structures

The aim of the study was to evaluate the possibility of using multilayer structures for light armour, in which the elements of the ceramic type SiC and Al2O3 were bonding by adhesive joins with antiballistic polyethylene and aramid fabrics. Ballistic resistance shells was determined using for this purpose the test stand constructed on the basis of helium gun and high-speed camera. It has been shown that the laminated structure composed of thin metal layers and aramid fabrics as well as polymer composites made of aramid fabric has lower ballistic resistance than loose fabric packs. It was also demonstrated the functionality of the use of the ceramic component as a separate package, which the ceramic plates are adhesive bonded between the two layers of sheet metal. There is also evidence that fabrics composed of thin layers of material poorly connected with each other, should not be adhesively bonded to the ceramic. It proposed the preparation of specimens, which best reconstruct the load of ceramic plates adhesive bonded to fabric, which are made of lightweight bulletproof vests and ballistic panels.

Badania odporności na przebicie klejonych struktur wielowarstwowych

Celem badań była ocena możliwości zastosowania opracowanych struktur wielowarstwowych do wytwarzania lekkich pancerzy, mogących znaleźć zastosowanie jako kuloodporne osłony balistyczne śmigłowców bojowych i innego lekkiego sprzętu wojskowego. Istotnym celem badań było również sprawdzenie możliwości łączenia metodą klejenia ceramiki typu SiC i Al2O3 z antybalistycznymi tkaninami polietylenowymi i aramidowymi. Odporność na przebicie była badana z wykorzystaniem stanowiska z działem helowym i ultraszybką kamerą. W wyniku przeprowadzonych badań stwierdzono, iż pakiety luźnych tkanin aramidowych charakteryzuje większa odporność na przebicie w porównaniu z kompozytami polimerowymi wytworzonymi z takich tkanin oraz kompozytami warstwowymi złożonymi z cienkich warstw metalowych i tkanin aramidowych. Ponadto zauważono, że warstwy ceramiczne znacznie zwiększają odporność na przebicie osłon balistycznych i ich stosowanie w takich osłonach wydaje się niezbędne oraz, że wklejenie płytek ceramicznych pomiędzy dwie cienkie blachy ze stopu aluminium i nie łączenie ich bezpośrednio z tkaninami aramidowymi zapewnia w przypadku uderzenia pociskiem zniszczenie małej powierzchni warstwy ceramicznej, a więc w małym stopniu zmniejsza właściwości ochronne osłony.

Examination of the influence of cross-impact load on bend strength properties of composite materials, used in aviation

Fibre reinforced composites are often used in airplane structures because of their specific strength. One type of the materials are layered composites (laminates) applied inter alia in aircraft’s covering production. Laminate is susceptible to damage resulting from impacts, the effect of which is usually invisible during macroscopic observation. The article presents results of a preliminary examination of layered composites obtained from an airplane element loaded impactly with low energy. During testing, pieces were loaded with 2.5; 5 and 10 J energy and then they were put on bend tests. The material bending strength after a shock load with 2.5 and 5 J energy remains almost unaltered, but for 10 J energy, it decreases by more than 30% in comparison to undamaged material. As a result of the examination, it was ascertained that in all cases the exact location of the damage could be difficult to find, which is a significant maintenance problem.

Badanie wpływu poprzecznych obciążeń udarowych na właściwości wytrzymałościowe materiałów kompozytowych stosowanych w lotnictwie

Kompozyty włókniste ze względu na bardzo wysoką wytrzymałość właściwą są często stosowane w konstrukcjach lotniczych. Jedną z odmian tych materiałów są kompozyty warstwowe (laminaty), z których wykonuje się m.in. elementy pokryć statków powietrznych. Laminat jest materiałem wrażliwym na działanie porzecznych obciążeń udarowych, często występujących podczas eksploatacji samolotów i śmigłowców. Praca prezentuje wyniki wstępnych badań kompozytów warstwowych pobranych z rzeczywistego elementu lotniczego, poddanych niskoenergetycznym obciążeniom udarowym. Podczas eksperymentu, próbki obciążano energiami o wartościach 2,5; 5 i 10 J, a następnie poddawano próbom zginania. Wytrzymałość materiału po obciążeniu udarowym z energiami 2,5 i 5 J pozostaje niemal niezmieniona, natomiast dla energii 10 J spada o ponad 30% w stosunku do materiału nieuszkodzonego. W wyniku badań stwierdzono również, że w każdym z przypadków mogą wystąpić trudności z lokalizacją uszkodzenia, co stanowi istotny problem eksploatacyjny.