ISSN 1507-2711
Our IF is 0,505


Wydawca(Publisher):Polskie Naukowo-Techniczne Towarzystwo Eksploatacyjne (Warszawa) - Polish Maintenance Society (Warsaw)       Patronat Naukowy(Scientific supervision): Polska Akademia Nauk o/Lublin  - Polish Akademy of Sciences Branch in Lublin      Członek(Member of): Europejskiej Federacji Narodowych Towarzystw Eksploatacyjnych  - European Federation of National Maintenance Societies

 


Submission On-Line

Publisher:
Polish Maintenance Society
(Warsaw)

Scientific supervision:
Polish Academy of Sciences Branch in Lublin

Member of:
European Federation
of National Maintenance Societies


Attention!

In accordance with the requirements of citation databases, proper citation of publications appearing in our Quarterly should include the full name of the journal in Polish and English without Polish diacritical marks, i.e., Eksploatacja i Niezawodnosc – Maintenance and Reliability.

SUBSCRIBE NEWSLETTER:

 

Privacy policy: Your personal data will be manually and electronically processed and used only to process your registration request and to keep you informed about all the EiN activities. In order to modify or cancel your data you can contact the Editorial Office at the following e-mail address:

 

 

MOST CITED

Update: 2014-11-29

1. RELIABILITY BASED OPTIMAL PREVENTIVE MAINTENANCE POLICY OF SERIES-PARALLEL SYSTEMS
By: Peng Wei; Huang Hong-Zhong; Zhang Xiaoling; et al.
EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Issue: 2 Pages: 4-7 Published: 2009

Times Cited: 19
2. PREDICTING THE TOOL LIFE IN THE DRY MACHINING OF DUPLEX STAINLESS STEEL
By: Krolczyk, Grzegorz; Gajek, Maksymilian; Legutko, Stanislaw
EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Volume: 15 Issue: 1 Pages: 62-65 Published: 2013

Times Cited: 10
3. AN ANALYSIS OF DEGRADATION OF VEHICLES IN OPERATION
By: Michalski Ryszard; Wierzbicki Slawomir
EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Issue: 1 Pages: 30-32 Published: 2008

Times Cited: 10
4. EFFICIENT RELIABILITY ANALYSIS OF SYSTEMS WITH FUNCTIONAL DEPENDENCE LOOPS
By: Xing, Liudong; Dugan, Joanne Bechta; Morrissette, Brock A.
EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Issue: 3 Pages: 65-69 Published: 2009

Times Cited: 9
5. A NEW FAULT TREE ANALYSIS METHOD: FUZZY DYNAMIC FAULT TREE ANALYSIS
By: Li, Yan-Feng; Huang, Hong-Zhong; Liu, Yu; et al.
EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Issue: 3 Pages: 208-214 Published: 2012

Times Cited: 8
6. SELECTED ASPECTS OF PHYSICAL STRUCTURES VULNERABILITY - STATE-OF-THE-ART
By: Valis, David; Vintr, Zdenek; Malach, Jindrich
EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Issue: 3 Pages: 189-194 Published: 2012

Times Cited: 8
7. ANALYTICAL MODEL OF THE SELF-HEATING EFFECT IN POLYMERIC LAMINATED RECTANGULAR PLATES DURING BENDING HARMONIC LOADING
By: Katunin, Andrzej
EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY
Issue: 4 Pages: 91-101 Published: 2010

Times Cited: 8

 

Visits since
10th May 2002

PageRank

porcelana dentystyczna

Multilayered system titanium – sol-gel coating – dental porcelain in dental prosthetics applications

In this work the results of the study of SiO2-TiO2 intermediate coatings on titanium substrate, produced by sol-gel method and low-fusing Triceram dental porcelain were presented. The microstructure of joint sol-gel coatings and adhesion tests of ceramic coatings according to PN-EN ISO 9693 standards were examined. The above studies led to the conclusion that the application of sol-gel intermediate coatings between metal substrate: titanium and Ti6Al4V ELI alloy and dental porcelain cause the increase of bond strength of metal-porcelain joint from 25% to 28% in comparison with metal substrate after sand blasting conventional treatment. The obtained metal - intermediate coating sol-gel - porcelain composite structure met the qualitative demands of dental implants enabling increasing their quality, durability and strength and may be used in the dental laboratories.

Wielowarstwowy układ tytan – powłoka zol-żel – porcelana dentystyczna do zastosowań w protetyce stomatologicznej

W pracy przedstawiono rezultaty badań powłok przejściowych SiO2-TiO2 nanoszonych na podłoże tytanowe metodą zol-żel oraz napalanej niskotopliwej porcelany dentystycznej Triceram. Analizowano mikrostrukturę połączenia powłok zol-żel i wykonano badania przyczepności warstwy ceramicznej w oparciu o normę PN-EN ISO 9693. Na postawie przeprowadzonych badań stwierdzono, że zastosowanie powłok przejściowych zol-żel pomiędzy metalem podłoża: tytanem i jego stopem Ti6Al4V ELI a porcelaną dentystyczną powoduje wzrost wytrzymałości połączenia od 25% do 28% w porównaniu do metalu bazowego poddanego jedynie konwencjonalnej obróbce-piaskowania. Uzyskany układ kompozytowy metal - powłoka pośrednia zol-żel-porcelana spełnia wymagania jakościowe stawiane implantom stomatologicznym umożliwiając podniesienie ich jakości, trwałości i wytrzymałości i może być stosowany w laboratoriach stomatologicznych.

Durability test of rice the metal-ceramics connection to application in dental prosthetics

The bond strength by three-point bending (according to PN-EN ISO 9693) of two combination: Ti/SiO2/Triceram and Ti/Triceram were evaluated. Coatings of SiO2 on base titanium were deposited using sol-gel method. Results showed that the bond strength of Ti/SiO2/Triceram in control group was significantly higher than the Ti/Triceram without intermediate layers SiO2. The analysis revealed: (1) a compact, homogenous SiO2 coating, and (2) that dental porcelain on SiO2 coatings shows good adhesion to base titanium and (3) that intermediate coatings may provide a durable joint between metal and porcelain.

Próba podwyższenia trwałości połączenia układu metal-ceramika do zastosowań w protetyce stomatologicznej

Przeprowadzono badania przyczepności dwóch kombinacji połączeń: Ti/SiO2/Triceram i Ti/ Triceram metodą trzypunktowego zginania (wg PN-EN ISO 9693). Powłoki SiO2 nanoszone były na tytanowe podłoże metodą zol-żel. Otrzymane wyniki badań wykazały większą przyczepność połączenia Ti/SiO2/Triceram niż porównywany układ połączenia Ti/Triceram bez warstwy przejściowej SiO2. Ponadto stwierdzono: (1) jednorodność warstw SiO2 (2) porcelana dentystyczna stosowana na warstwach SiO2 wykazuje dobrą przyczepność do podłoża tytanowego oraz (3) warstwy pośrednie mogą dostarczyć trwałego połączenia pomiędzy metalem a porcelaną.